Fourier Domain OCT for Whole Eye Segment Imaging

KONG Ruiming, GUO Chunfeng, WANG Huan, LIU Wenlu, DAI Cuixia

PDF(1945 KB)
Chinese Journal of Light Scattering ›› 2019, Vol. 31 ›› Issue (2) : 112-122. DOI: 10.13883/j.issn1004-5929.201902002
Overview

Fourier Domain OCT for Whole Eye Segment Imaging

  • KONG Ruiming1, GUO Chunfeng1, WANG Huan1, LIU Wenlu2, DAI Cuixia1*
Author information +
History +

Abstract

Millions of people are affected by eye diseases which can affect the shape and dimensions of the whole eye.For examination of ocular accommodation and pathological changes caused by these diseases,high resolution imaging of the whole eye segments OCT system is desired.However,limited by the imaging depth,traditional Fourier Domain Optical Coherence Tomography (FD-OCT)can't be used for real time whole eye segment imaging.In recent years,techniques for depth extended FD-OCT system especially for whole eye segment imaging has been developed.Application on eye parameters measurement and eye accommodation studies were successfully performed.In this paper,both of whole eye FD-OCT techniques and the application were reviewed.Potential clinical application of these techniques may be in the detection of the pathological changes of the whole eye,and whole eye segment FD-OCT system also provides a powerful imaging method for ophthalmic research.

Key words

Optical Coherence Tomography / Ophthalmology / whole eye segment imaging

Cite this article

Download Citations
KONG Ruiming, GUO Chunfeng, WANG Huan, LIU Wenlu, DAI Cuixia. Fourier Domain OCT for Whole Eye Segment Imaging. Chinese Journal of Light Scattering. 2019, 31(2): 112-122 https://doi.org/10.13883/j.issn1004-5929.201902002

References

[1] FLEDELIUS H C.Ultrasound in ophthalmology[J].Ultrasound Med Biol,1997,23,365-375.
[2] RESTORI M.Imaging the vitreous:optical coherence tomography and ultrasound imaging[J].Eye,22,2008,1251-1256.
[3] KORETZ J E,STRENK S A,STRENK L M,et al.Scheimpflug and high-resolution magnetic resonance imaging of the anterior segment:a comparative study[J].Opt Soc Am,2004,21,346-354.
[4] WOLFFSOHN J S,DAVIES L N.Advances in anterior segment imaging[J].Curr Opin Ophthalmol,2007,18,32-38.
[5] HUANG D,SWANSON E A,LIN C P,et al.Optical coherence tomography[J].Science,1991,254,1178-1181.
[6] FERCHER A F,DREXLER W,HITZENBERGER C K,et al.Optical coherence tomography-principles and applications[J].Rep Prog Phys,2003,66,239-303.
[7] FERCHER A F,HITZENBERGER C K,KAMP G,et al.Measurement of intraocular distances by backscattering spectral interferometry[J].Opt Commun,1995,117(1),43-48.
[8] LEITGEB R A,HITZENBERGER C K,FERCHER A F.Performance of Fourier Domain vs Time Domain optical coherence tomography[J].Opt Express,2003,11,889-894.
[9] BOER J F,CENSE B,PARK B H,et al.Improved signal to noise ratio in spectral domain compared with time domain optical coherence tomography[J].Opt Lett,2003,28,2067-2069.
[10] WALSH A C.Binocular optical coherence tomography[J].Ophthal Surg Las Im,2011,42,S95-S105.
[11] LI P,AN L,LAN G P M,et al. Extended imaging depth to 12 mm for 1050-nm spectral domain optical coherence tomography for imaging the whole anterior segment of the human eye at 120-kHz A-scan rate[J].Biomed Opt,2013,18(1),016012-1-016012-4.
[12] ZHOU C Q,WANG J H,JIAO S L.Dual channel dual focus optical coherence tomography for imaging accommodation of the eye[J].Opt Express,2007,17,8947-8955.
[13] FERCHER A F,LEITGEB R,HITZENBERGER C K, et al.Complex spectral interferometry OCT[J].Proc SPIE,1999,3564,173-178.
[14] WOJTKOWSKI M,KOWALCZYK A,LEITGEB R,et al. Full range complex spectral optical coherence tomography technique in eye imaging[J].Opt Lett,2002,27,1415-1417.
[15] LEITGEB R A,HITZENBERGER C K,FERCHER A F,et al. Phase shifting algorithm to achieve high-speed long-depth-range probing by frequency-domain optical coherence tomography[J].Opt Lett,2003,28,2201-2203.
[16] GÖTZINGER E,PIRCHER M,LEITGEB R, et al.High speed full range complex spectral domain optical coherence tomography[J].Opt Express,2005,13,583-594.
[17] BAUMANN B,PIRCHER M,GÖTZINGER E,et al.Full range complex spectral domain optical coherence tomography without additional phase shifters[J].Opt Express,2007,15,13375-13387.
[18] AN L,WANG R.Use of a scanner to modulate spatial interferograms for in vivo full-range Fourier-domain optical coherence tomography[J].Opt Lett,2007,32,3423-3425.
[19] LEITGEB R,MICHAELY R,LASSER T,et al.Complex ambiguity-free Fourier domain optical coherence tomography through transverse scanning[J].Opt Lett,2007,32,3453-3455.
[20] JUNGWIRTH J,BAUMANN B,PIRCHER M,et al.Extended in vivo anterior eye-segment imaging with full-range complex spectral domain optical coherence tomography[J].J Biomed Opt,2009,14,050501.
[21] DHALLA A H.Simultaneous swept source optical coherence tomography of the anterior segment and retina using coherence revival[J].Opt lett,2013,37(11):1883-1885.
[22] FURUKAWA H,HIRO-OKA H,SATOH N,et al. Full-range imaging of eye accommodation by high-speed long-depth range optical frequency domain imaging[J].Biomed Opt Express,2010,1(5),1491-1501.
[23] GORA M,KARNOWSKI K,SZKULMOWSKI M,et al. Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range[J].Opt Express,2009,17(17),14880-14894.
[24] POTSAID B,BAUMANN B,HUANG D,et al. Ultrahigh speed 1050nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second[J].Opt Express,2010,18(19),20029-20048.
[25] GRULKOWSKI I,LIU J J,POTSAID B,et al. Retinal,anterior segment and full eye imaging using ultrahigh speed swept source OCT with verticalcavity surface emitting lasers,[J].Biomed Opt Express,2012,3(11),2733-2751.
[26] FERCHER A F,HITZENBERGER C K,KAMP G,et al. Measurement of intraocular distances by backscattering spectral interferometry[J].Opt Commun,1995,117,43-48.
[27] HÄUSLE G,LINDNER M W.Coherence radarand spectralradar-new tools for dermatological diagnosis[J].J Biomed Opt,1998,3,21-31.
[28] ZHOU C Q,WANG J H,JIAO S L.Dual channel dual focus optical coherence tomography for imaging accommodation of the eye[J].Opt Express,2009,17,8947-8955.
[29] FERCHER A F,LEITGEB R,HITZENBERGER C K,et al. Complex spectral interferometry OCT[J].Proc SPIE,1999,3564,173-178.
[30] WOJTKOWSKI M,KOWALCZYK A,LEITGEB R,et al.Fullrange complex spectral optical coherence tomography technique ineye imaging[J].Opt Lett,2002,27,1415-1417.
[31] LEITGEB R A,HITZENBERGER C K,FERCHER A F,et al. Phaseshifting algorithm to achieve high-speed long-depth-rangeprobing by frequency-domain optical coherence tomography[J].Opt Lett,2003,28,2201-2203.
[32] GÖTZINGER E,PIRCHER M,LEITGEB R,et al.Highspeed full range complex spectral domain optical coherence tomography[J].Opt Express,2005,13,583-594.
[33] BAUMANN B,PIRCHER M,GÖTZINGER E,et al.Fullrange complexspectral domain optical coherence tomography without additional phase shifters[J].Opt Express,2007,15,13375-13387.
[34] AN L,WANG R.Use of a scanner to modulate spatial interferograms for in vivo full-range Fourier-domain optical coherence tomography[J].Opt Lett,2007,32,3423-3425.
[35] LEITGEB R,MICHAELY R,LASSER T,et al.Complexambiguity-free Fourier domain optical coherence tomographythrough transverse scanning[J].Opt Lett,2007,32,3453-3455.
[36] JUNGWIRTH J,BAUMANN B,PIRCHER M,et al.Extended in vivo anterior eye-segment imaging with full-range complex spectral domain optical coherence tomography[J].J Biomed Opt,2009,14,050501.
[37] DAI C X,ZHOU C Q,FAN S H, et al.Optical coherent tomography for whole eye segment imaging[J].Opt Express,2012,20(6):6109-6115.
[38] FAN S H,SUN Y,DAI C X,et al.Accommodation-induced variations in retinal thickness measured by spectral domain optical coherence tomography[J].J Biomed Opt,2014,19(9):096012-1-096012-8.
[39] YONG S,FAN S H,DAI C X,et al. Noninvasive imaging and measurement of accommodation using dual-channel SD-OCT[J].Curr Eye Res,2014,39(6):611-619.
[40] FAN S H,SUN Y,DAI C X,et al. The Whole Eye Segment Imaging and Measurement with Dual Channel SD-OCT[J].Ophthalmic Surgery,Lasers and Imaging retina,2014,28(12):317-322.
[41] JEONG H W.Spectral-domain OCT with dual illumination and interlaced detection for simultaneous anterior segment and retina imaging[J].Opt Express,2012,20(17):19148-19159.
[42] RUGGERI M.Imaging and full-length biometry of the eye during accommodation using spectral domain OCT with an optical switch[J].Biomed Optics Express,2012,3(7):1506-1520.
[43] KIM H J,KIM P U,HYEON M G,et al. High-resolution,dual-depth spectral-domain optical coherence tomography with interlaced detection for whole-eye imaging[J].Appl Opt,2016,55(26)7212-7217.
[44] CHINN S R,SWANSON E A,FUJIMOTO J G.Optical coherence tomography using a frequency-tunable optical source[J].Opt Lett,1997,22(5),340-342.
[45] YUN S H,BOUDOUX C,TEARNEY G J,et al. High-speed wavelength-swept semiconductor laser with a polygon-scanner-based wavelength filter[J].Opt Lett,2003,28(20),1981-1983.
[46] CHOMA M A,HSU K,IZATT J A.Swept source optical coherence tomography using an all-fiber 1300-nm ring laser source[J].J Biomed Opt,2005,10(4),044009.
[47] HUBER R,WOJTKOWSKI M,TAIRA K,et al, Amplified,frequency swept lasers for frequency domain reflectometry and OCT imaging:design and scaling principles[J].Opt Express,2005,13(9),3513-3528.
[48] GOLDBERG B D,MOTAGHIAN S M,NEZAM,et al. Miniature swept source for point of care optical frequency domain imaging[J].Opt Express,2009,17(5),3619-3629.
[49] HUBER R,WOJTKOWSKI M,FUJIMOTO J G.Fourier Domain Mode Locking (FDML):A new laser operating regime and applications for optical coherence tomography,[J].Opt Express,2006,14(8),3225-3237.
[50] WIESER W,BIEDERMANN B R,KLEIN T,et al. Multi-megahertz OCT:High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second[J].Opt Express,2010,18(14),14685-14704.
[51] LIU A Q,ZHANG X M.A review of MEMS external-cavity tunable lasers[J].J Micromech Microeng,2007,17(1),R1-R13.
[52] JAYARAMAN V,JIANG J,LI H,et al.OCT imaging up to 760 kHz axial scan rate using single-mode 1310 nm MEMS-tunable VCSELs with >100 nm tuning range[J].In Conference on Lasers and Electro-Optics,Technical Digest (CD),(Optical Society of America,2011),paper PDPB2.
[53] POTSAID B,JAYARAMAN V,FUJIMOTO J G,et al.MEMS tunable VCSEL light source for ultrahigh speed 60 kHz-1 MHz axial scan rate and long range centimeter class OCT imaging[J].Proc SPIE,2012,8213,82130M,82130M-8.
[54] ZHONG J G.Whole eye axial biometry during accommodation using ultra-long scan depth optical coherence tomography[J].American Journal of Ophthalmology,2014,157(5):1064-1069.
[55] FAN S H,LI L,LI Q,et al.Dual band dual focus optical coherence tomography for imaging the whole eye segment[J].Biomed Optics Express,2015,6(7):2481-2493.
[56] CHANG Y C,LIU K,FREITAS C D,et al.Assessment of eye length changes in accommodation using dynamic extended-depth OCT[J].Biomed Optics Express,2017,8(5):2709-2019.
[57] DHALLA A H.Simultaneous swept source optical coherence tomography of the anterior segment and retina using coherence revival[J].Opt Lett,2013,37(11):1883-1885.
[58] GRULKOWSKI I.Swept source optical coherence tomography and tunable lens technology for comprehensive imaging and biometry of the whole eye[J].Optical,2018(5):1.
[59] SWANSON E A,IZATT J,LIN C,et al.In vivo retinal imaging by optical coherence tomography[J].Opt Lett,1993,18(21),1864-1866.
PDF(1945 KB)

151

Accesses

0

Citation

Detail

Sections
Recommended

/